Send Message
products
products
Home > products > LSZH Cable > Feichun SIENOPYR(180) (N)HXSGAFHXOE 3,6/6KV OM 150C : High-Temperature Power Cables for Reliable Rolling Stock Performance

Feichun SIENOPYR(180) (N)HXSGAFHXOE 3,6/6KV OM 150C : High-Temperature Power Cables for Reliable Rolling Stock Performance

Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: VDE 0250 Part 814

Model Number: (N)HXSGAFHXOE 3,6/6KV

Payment & Shipping Terms

Minimum Order Quantity: 200 Meter

Price: 10-50 USD per meter, price varies according to specifications

Packaging Details: Cable Reels or Packaging Bags

Delivery Time: 15-30 Work Day

Payment Terms: T/T, Western Union

Supply Ability: 18,000 meters per week

Highlight:
High Conductivity:
Optimal Power Transmission Efficiency
Temperature Rating:
-40°C To +90°C
Chemical Resistant:
Resists Damage From Industrial Chemicals
Braid:
With Or Without Tinned Copper
Application:
Indoor/Outdoor
Rohs Compliant:
Yes
Urban Expansion:
Facilitates City Growth
Flexibility:
Easy Adaptation To Tunnel Contours
Installation Method:
Indoor/Outdoor
Flame Resistance:
Superior Fire Safety
Smoke Emission:
Low
Type:
Single Mode
Conductor Size:
14 AWG
Flexible:
Yes
High Conductivity:
Optimal Power Transmission Efficiency
Temperature Rating:
-40°C To +90°C
Chemical Resistant:
Resists Damage From Industrial Chemicals
Braid:
With Or Without Tinned Copper
Application:
Indoor/Outdoor
Rohs Compliant:
Yes
Urban Expansion:
Facilitates City Growth
Flexibility:
Easy Adaptation To Tunnel Contours
Installation Method:
Indoor/Outdoor
Flame Resistance:
Superior Fire Safety
Smoke Emission:
Low
Type:
Single Mode
Conductor Size:
14 AWG
Flexible:
Yes
Feichun SIENOPYR(180) (N)HXSGAFHXOE 3,6/6KV OM 150C : High-Temperature Power Cables for Reliable Rolling Stock Performance

Feichun SIENOPYR(180) (N)HXSGAFHXOE 3,6/6KV OM 150C : High-Temperature Power Cables for Reliable Rolling Stock Performance

 

 

 

Feichun SIENOPYR(180) cables are at the forefront of innovation in high-temperature power cable technology, specifically designed for railway rolling stock.

 

 

 

 

These halogen-free, single-core cables offer exceptional fire performance, withstand demanding mechanical and thermal environments, and comply with stringent industry standards.

 

 

 

 

This article provides an in-depth guide to the SIENOPYR(180) (N)HXSGAFHXOE 3.6/6KV OM 150°C cables, emphasizing their construction, practical applications, compliance with safety standards, and installation best practices.

 

 

 


Feichun SIENOPYR(180) (N)HXSGAFHXOE 3,6/6KV OM 150C : High-Temperature Power Cables for Reliable Rolling Stock Performance 0

 

I. Introduction: Meeting the Demands of Modern Rail Transport

 

 

 

The modern railway industry faces stringent safety regulations, increased power requirements, and demands for sustainability. Electrical components, particularly cables, play a vital role in ensuring the reliability and safety of these systems.

 

 

 

 

Feichun stands out as a leader in specialized cable solutions, offering products engineered to meet the challenges of modern rail transport. The SIENOPYR(180) cables are designed to:

 

 

 

  • Perform in high-temperature environments.

 

 

 

  • Comply with fire safety standards.

 

 

 

 

  • Provide reliability under conditions involving limited flexing or fixed wiring in rolling stock.

 

 

 

 

  • Meet the fire safety hazard levels HL1, HL2, and HL3, per DIN EN 45545-1:2013.

 

 


 

 

II. Cable Construction and Technical Specifications: Designed for Extreme Conditions

 

 

 

The SIENOPYR(180) cables are engineered for durability and safety. Let’s delve into their core components and technical specifications.

 

 

 

Key Components

 

 

 

 

Component Description
Conductor Tinned, finely stranded Class 5 copper per DIN EN 60228. Ensures flexibility, corrosion resistance, and efficient electrical conductivity.
Insulation Cross-linked Silicone Insulating Rubber (SIR), type EI 112. Halogen-free for fire safety and minimal smoke emission.
Outer Sheath Silicone rubber. Provides UV resistance, durability in harsh environments, and thermal stability.
Shielding (optional) Tinned copper braiding for EMC protection, reducing interference in sensitive electronic systems.

 

 

Electrical Characteristics

 

 

 

 

 

 

Characteristic Value
Rated Voltage (U0/U) 3.6/6 (7.2) kV. Suitable for traction circuits, auxiliary systems, and electric heating.
Test Voltage 11 kV. Ensures insulation reliability under extreme conditions.
Maximum Conductor Temperature 150°C. Ideal for high-temperature areas near braking systems and engines.
Short Circuit Temperature 350°C. Provides enhanced safety during fault conditions.

 

 

Mechanical Properties

 

 

Property Specification
Tensile Strength ≥ 15 N/mm². Ensures mechanical durability.
Bending Radius Fixed Installation: 4xD (D≤12mm) or 5xD (D>12mm).
Flexible Installation: 10xD.
Restricted Movement: 8xD.
Laying Temperature -50°C minimum. Suitable for extreme cold environments.
Operating Temperature Range -50°C to +150°C. Ideal for applications exposed to temperature fluctuations.

 

 

Feichun SIENOPYR(180) (N)HXSGAFHXOE 3,6/6KV OM 150C : High-Temperature Power Cables for Reliable Rolling Stock Performance 1

 

 

III. Compliance with Industry Standards: Ensuring Safety and Performance

 

 

 

Feichun SIENOPYR(180) cables are meticulously designed to meet or exceed industry standards for safety and performance.

 

 

 

Key Standards

 

 

Standard Purpose and Relevance
DIN EN 50382 Rolling stock cables with special fire behavior.
DIN EN 50305 Establishes test conditions for mechanical and electrical reliability in rolling stock cables.
DIN EN 45545 Fire protection for railway vehicles, including hazard levels HL1, HL2, and HL3.
DIN EN 61034-2 Measures smoke density, crucial for visibility during fire emergencies.
DIN EN 60228 Specifies conductor quality for durability and efficiency.
DIN EN 50343 Guidelines for installation of cables in railway environments.

 

 

These standards ensure:

 

 

  • Fire safety compliance for passenger and equipment protection.

 

  • Interoperability across different railway systems.

 

  • Long-lasting performance in challenging environments.

 

 


IV. Practical Considerations and Potential Challenges: Real-World Applications

Installation Best Practices

 

 

 

 

Proper installation ensures optimal performance and extends the lifespan of SIENOPYR(180) cables.

 

 

 

 

 

Aspect Recommendations
Cable Handling Avoid exceeding the minimum bending radius during installation to prevent insulation damage.
Storage Store in dry, UV-protected areas to maintain sheath integrity.
Routing Route cables to minimize vibration and abrasion. Use protective conduits where necessary.
Terminations Use high-temperature-rated glands and connectors for proper sealing and electrical performance.

 

 

Environmental Challenges

 

 

 

SIENOPYR(180) cables are built to endure harsh conditions, but specific precautions enhance their effectiveness:

 

 

 

Challenge Solution
Extreme Temperatures Use heat shields in areas with prolonged exposure to high temperatures (e.g., near brakes).
Vibration Secure cables with high-strength clamps to avoid mechanical wear.
Chemical Exposure Silicone outer sheaths resist oils and greases but should be inspected regularly for damage.
UV Radiation UV-resistant sheath ensures long-term outdoor performance.

 

Feichun SIENOPYR(180) (N)HXSGAFHXOE 3,6/6KV OM 150C : High-Temperature Power Cables for Reliable Rolling Stock Performance 2

 

 

 

 

Maintenance and Inspection

 

 

Regular inspection is key to maintaining performance and safety:

 

 

 

Inspection Task Frequency
Visual Checks Quarterly. Look for signs of abrasion, sheath degradation, or mechanical damage.
Electrical Testing Annually. Measure insulation resistance and conductor integrity.
Replacement Planning Assess service life based on stress levels and environmental conditions.

 

V. Conclusion: The Advantages of Feichun SIENOPYR(180)

 

 

Feichun SIENOPYR(180) cables are the optimal choice for railway rolling stock, offering:

 

 

  • Exceptional fire safety, meeting HL1, HL2, and HL3 requirements.

 

  • High-temperature resistance for demanding environments.

 

  • Compliance with industry standards, ensuring safety and reliability.

 

 

  • Durability in mechanical and thermal extremes.

 

 

Choose Feichun for unmatched reliability and safety in your railway applications. For more information or technical assistance, contact Feichun today.

 

 


This comprehensive guide equips professionals with the knowledge needed to install, maintain, and maximize the performance of SIENOPYR(180) cables.