Product Details
Place of Origin: Hefei Anhui China
Brand Name: FeiChun™
Certification: VDE 0250 Part 814
Model Number: (N)HXSGAFHXOE 3,6/6KV
Payment & Shipping Terms
Minimum Order Quantity: 200 Meter
Price: 10-50 USD per meter, price varies according to specifications
Packaging Details: Cable Reels or Packaging Bags
Delivery Time: 15-30 Work Day
Payment Terms: T/T, Western Union
Supply Ability: 18,000 meters per week
High Conductivity: |
Optimal Power Transmission Efficiency |
Temperature Rating: |
-40°C To +90°C |
Chemical Resistant: |
Resists Damage From Industrial Chemicals |
Braid: |
With Or Without Tinned Copper |
Application: |
Indoor/Outdoor |
Rohs Compliant: |
Yes |
Urban Expansion: |
Facilitates City Growth |
Flexibility: |
Easy Adaptation To Tunnel Contours |
Installation Method: |
Indoor/Outdoor |
Flame Resistance: |
Superior Fire Safety |
Smoke Emission: |
Low |
Type: |
Single Mode |
Conductor Size: |
14 AWG |
Flexible: |
Yes |
High Conductivity: |
Optimal Power Transmission Efficiency |
Temperature Rating: |
-40°C To +90°C |
Chemical Resistant: |
Resists Damage From Industrial Chemicals |
Braid: |
With Or Without Tinned Copper |
Application: |
Indoor/Outdoor |
Rohs Compliant: |
Yes |
Urban Expansion: |
Facilitates City Growth |
Flexibility: |
Easy Adaptation To Tunnel Contours |
Installation Method: |
Indoor/Outdoor |
Flame Resistance: |
Superior Fire Safety |
Smoke Emission: |
Low |
Type: |
Single Mode |
Conductor Size: |
14 AWG |
Flexible: |
Yes |
Feichun SIENOPYR(180) cables are at the forefront of innovation in high-temperature power cable technology, specifically designed for railway rolling stock.
These halogen-free, single-core cables offer exceptional fire performance, withstand demanding mechanical and thermal environments, and comply with stringent industry standards.
This article provides an in-depth guide to the SIENOPYR(180) (N)HXSGAFHXOE 3.6/6KV OM 150°C cables, emphasizing their construction, practical applications, compliance with safety standards, and installation best practices.
The modern railway industry faces stringent safety regulations, increased power requirements, and demands for sustainability. Electrical components, particularly cables, play a vital role in ensuring the reliability and safety of these systems.
Feichun stands out as a leader in specialized cable solutions, offering products engineered to meet the challenges of modern rail transport. The SIENOPYR(180) cables are designed to:
The SIENOPYR(180) cables are engineered for durability and safety. Let’s delve into their core components and technical specifications.
Component | Description |
---|---|
Conductor | Tinned, finely stranded Class 5 copper per DIN EN 60228. Ensures flexibility, corrosion resistance, and efficient electrical conductivity. |
Insulation | Cross-linked Silicone Insulating Rubber (SIR), type EI 112. Halogen-free for fire safety and minimal smoke emission. |
Outer Sheath | Silicone rubber. Provides UV resistance, durability in harsh environments, and thermal stability. |
Shielding (optional) | Tinned copper braiding for EMC protection, reducing interference in sensitive electronic systems. |
Characteristic | Value |
---|---|
Rated Voltage (U0/U) | 3.6/6 (7.2) kV. Suitable for traction circuits, auxiliary systems, and electric heating. |
Test Voltage | 11 kV. Ensures insulation reliability under extreme conditions. |
Maximum Conductor Temperature | 150°C. Ideal for high-temperature areas near braking systems and engines. |
Short Circuit Temperature | 350°C. Provides enhanced safety during fault conditions. |
Property | Specification |
---|---|
Tensile Strength | ≥ 15 N/mm². Ensures mechanical durability. |
Bending Radius | Fixed Installation: 4xD (D≤12mm) or 5xD (D>12mm). Flexible Installation: 10xD. Restricted Movement: 8xD. |
Laying Temperature | -50°C minimum. Suitable for extreme cold environments. |
Operating Temperature Range | -50°C to +150°C. Ideal for applications exposed to temperature fluctuations. |
Feichun SIENOPYR(180) cables are meticulously designed to meet or exceed industry standards for safety and performance.
Standard | Purpose and Relevance |
---|---|
DIN EN 50382 | Rolling stock cables with special fire behavior. |
DIN EN 50305 | Establishes test conditions for mechanical and electrical reliability in rolling stock cables. |
DIN EN 45545 | Fire protection for railway vehicles, including hazard levels HL1, HL2, and HL3. |
DIN EN 61034-2 | Measures smoke density, crucial for visibility during fire emergencies. |
DIN EN 60228 | Specifies conductor quality for durability and efficiency. |
DIN EN 50343 | Guidelines for installation of cables in railway environments. |
These standards ensure:
Proper installation ensures optimal performance and extends the lifespan of SIENOPYR(180) cables.
Aspect | Recommendations |
---|---|
Cable Handling | Avoid exceeding the minimum bending radius during installation to prevent insulation damage. |
Storage | Store in dry, UV-protected areas to maintain sheath integrity. |
Routing | Route cables to minimize vibration and abrasion. Use protective conduits where necessary. |
Terminations | Use high-temperature-rated glands and connectors for proper sealing and electrical performance. |
SIENOPYR(180) cables are built to endure harsh conditions, but specific precautions enhance their effectiveness:
Challenge | Solution |
---|---|
Extreme Temperatures | Use heat shields in areas with prolonged exposure to high temperatures (e.g., near brakes). |
Vibration | Secure cables with high-strength clamps to avoid mechanical wear. |
Chemical Exposure | Silicone outer sheaths resist oils and greases but should be inspected regularly for damage. |
UV Radiation | UV-resistant sheath ensures long-term outdoor performance. |
Regular inspection is key to maintaining performance and safety:
Inspection Task | Frequency |
---|---|
Visual Checks | Quarterly. Look for signs of abrasion, sheath degradation, or mechanical damage. |
Electrical Testing | Annually. Measure insulation resistance and conductor integrity. |
Replacement Planning | Assess service life based on stress levels and environmental conditions. |
Feichun SIENOPYR(180) cables are the optimal choice for railway rolling stock, offering:
Choose Feichun for unmatched reliability and safety in your railway applications. For more information or technical assistance, contact Feichun today.
This comprehensive guide equips professionals with the knowledge needed to install, maintain, and maximize the performance of SIENOPYR(180) cables.