Product Details

Place of Origin: Hefei Anhui China

Brand Name: FeiChun™

Certification: AS/NZS 1802 AS/NZS 2802:2000 AS/NZS 1125:2001 And AS/NZS 2802:2003

Model Number: Type 450 Mining Cable

Payment & Shipping Terms

Minimum Order Quantity: 800 Meter

Packaging Details: Cable Reels or Packaging Bags

Payment Terms: T/T, Western Union

Get Best Price
Highlight:

compact design Type 450 mining cable

,

rugged construction Type 450 mining cable

Jacket Material:
Neoprene
Impact Resistant:
Guards Against Impact Damage
Custom Power Solutions:
Tailored For Equipment Needs
Abrasion Resistance:
High
Abrasion Resistant:
Yes
Armor Type:
Steel Wire Armor
Long Service Life:
Built For Longevity
Optimized For Quarrying:
Designed For Quarrying Applications
Versatile Compatibility:
Fits Various Equipment Configurations
Bending Radius:
10 X Cable Diameter
Jacket Material:
Neoprene
Impact Resistant:
Guards Against Impact Damage
Custom Power Solutions:
Tailored For Equipment Needs
Abrasion Resistance:
High
Abrasion Resistant:
Yes
Armor Type:
Steel Wire Armor
Long Service Life:
Built For Longevity
Optimized For Quarrying:
Designed For Quarrying Applications
Versatile Compatibility:
Fits Various Equipment Configurations
Bending Radius:
10 X Cable Diameter
Type 450 Mining Cable Are Compact In Design Rugged Construction Type 450.3 & 3.3kV Type 450.6 & 6.6kV Type 450.11 & 11kV

Type 450 Mining Cable is engineered with compact dimensions yet boasts a robust structure, making it ideal for various mining applications where space is limited but durability is paramount.

 

 

 

Power Cores         Core screen   Pilot core   Sheath   Mass  
Crosssection
mm2
Strand
no/mm
Conductor
Diameter
Nom. mm
Insulation
thickness
mm
Insulation
diameter
Nom. mm
Braid wires
no/mm
Crosssection
mm2
Strand
no/mm
Insulation
thickness
mm
Thickness
mm
Overall diameter
Nom. Mm
Approx.
cable weight
kg/km
Copper weight
kg/km
Type 450.3 3.3/3.3kV Class 1 insulation                
16 126/0,40 5.7 2.2 12.4 128/0.25 6.3 114/0.30 1.4 4.5 42.8 2.65 876
25 209/0,40 7.2 2.2 13.9 118/0.30 8.3 114/0.30 1.4 4.8 46.9 3.35 1.193
35 285/0,40 8.5 2.2 15.2 127/0.30 9 114/0.30 1.4 5.1 50.3 3.9 1.501
50 380/0,40 10 2.4 17.1 141/0.30 10 171/0.30 1.4 5.6 55.5 4.85 2.077
70 203/0,67 12 2.4 19.1 117/0.40 14.7 51/0.67 1.4 6 61.1 6.35 2.958
95 259/0,67 13.2 2.4 20.3 123/0.40 15.5 70/0.67 1.6 6.3 64.3 7.3 3.894
120 336/0,67 15.3 2.4 22.4 135/0.40 17 84/0.67 1.6 6.4 69 8.65 4.801
150 427/0,67 17.1 2.4 24.2 144/0.40 18.1 112/0.67 1.6 6.6 73.3 10.2 5.979
185 518/0,67 19.2 2.4 26.3 144/0.40 18.1 132/0.67 1.6 6.7 78.1 11.7 7.192
240 672/0,67 21.8 2.4 28.9 136/0.50 26.7 168/0.67 1.6 6.9 84.5 14.4 9.389
300 854/0,67 24.4 2.4 31.5 144/0.50 28.3 228/0.67 1.6 7 90.4 17.4 11.771
Type 450.6 6.6/6.6kV Class 1 insulation                
16 126/0,40 5.7 3 14 118/0.30 8.3 114/0.30 1.4 5 47.6 3.15 934
25 209/0,40 7.2 3 15.5 129/0.30 9.1 114/0.30 1.6 5.2 51.2 3.8 1.216
35 285/0,40 8.5 3 16.8 139/0.30 9.8 114/0.30 1.6 5.5 54.7 4.4 1.524
50 380/0,40 10 3 18.3 149/0.30 10.5 171/0.30 1.6 5.9 58.8 5.3 2.091
70 203/0,67 12 3 20.3 123/0.40 15.5 51/0.67 1.6 6.3 64.3 6.8 2.981
95 259/0,67 13.2 3 21.5 130/0.40 16.3 70/0.67 1.8 6.4 67.1 7.7 3.917
120 336/0,67 15.3 3 23.6 141/0.40 17.7 84/0.67 1.8 6.5 71.9 9.1 4.822
150 427/0,67 17.1 3 25.4 144/0.40 18.1 112/0.67 1.8 6.6 76 10.7 5.979
185 518/0,67 19.2 3 27.5 144/0.40 18.1 132/0.67 1.8 6.8 80.9 12.2 7.192
240 672/0,67 21.8 3 30.1 141/0.50 27.7 168/0.67 1.8 7 87.4 15 9.418
300 854/0,67 24.4 3 32.7 144/0.50 28.3 228/0.67 1.8 7.1 93.2 17.9 11.771
Type 450.11 11/11kV Class 1 insulation                
25 209/0,40 7.2 5 19.6 120/0.40 15.1 114/0.30 2 6.3 62.8 5.4 1.389
35 285/0,40 8.5 5 20.9 127/0.40 16 114/0.30 2 6.4 65.8 6 1.703
50 380/0,40 10 5 22.4 135/0.40 17 171/0.30 2 6.5 69.3 6.9 2.279
70 203/0,67 12 5 24.4 144/0.40 18.1 51/0.67 2 6.6 73.8 8.25 3.056
95 259/0,67 13.2 5 25.6 144/0.40 18.1 70/0.67 2.2 6.7 76.6 9.25 3.969
120 336/0,67 15.3 5 27.7 144/0.40 18.1 84/0.67 2.2 6.9 81.6 10.8 4.833
150 427/0,67 17.1 5 29.5 139/0.50 27.3 112/0.67 2.2 7 86.1 12.6 6.244
185 518/0,67 19.2 5 31.6 144/0.50 28.3 132/0.67 2.2 7.1 90.8 14.3 7.486
240 627/0,67 21.8 5 34.2 144/0.50 28.3 168/0.67 2.2 7.3 96.8 16.9 9.435
300 854/0,67 24.4 5 36.8 144/0.50 28.3 228/0.67 2.2 7.4 102.7 20 11.771
Type 450.22 22/22KV Class 1 insulation                
35 285/0,40 8.5 7.6 26.3 144/0.40 18.1 114/0.30 2.5 6.8 78.4 8.05 1.763
50 380/0,40 10 7.6 27.8 144/0.40 18.1 171/0.30 2.5 6.9 81.8 9 2.31
70 203/0,67 12 7.6 29.8 140/0.50 27.5 51/0.67 2.5 7 86.8 10.7 3.327
95 259/0,67 13.2 7.6 31 144/0.50 28.3 70/0.67 2.5 7.2 89.8 11.8 4.263
120 336/0,67 15.3 7.6 33.1 144/0.50 28.3 84/0.67 2.5 7.3 94.5 13.5 5.127
150 427/0,67 17.1 7.6 34.9 144/0.50 28.3 112/0.67 2.5 7.4 98.6 15.2 6.273
185 518/0,67 19.2 7.6 37 144/0.50 28.3 132/0.67 2.5 7.5 103.4 17 7.486
240 627/0,67 21.8 7.6 39.6 144/0.50 28.3 168/0.67 2.5 7.7 109.4 19.8 9.435
300 854/0,67 24.4 7.6 42.2 144/0.50 28.3 228/0.67 2.5 7.9 115.4 23.1 11.771

 

 

 

CONDUCTOR

 

Featuring an electrolytic, multiple-stranded circular flexible tinned copper wire (rope lay) in compliance with AS/NZS 1125-2.10 standards, the conductor ensures efficient power transmission while maintaining flexibility, essential for dynamic mining environments.

 

 

 

 

SEPARATOR

 

 

A semiconducting layer is applied over both power and earth conductors, enhancing the cable’s electrical properties and minimizing the risk of signal interference or distortion. This layer contributes to the overall reliability and performance of the cable in mining applications.

 

 

INSULATION

 

 

The cable’s insulation consists of XR-EP-90 (Class 1) material, according to AS/NZS 3808 standards. While earth cores remain uninsulated, the insulation on power conductors ensures high electrical resistance and thermal stability, safeguarding against electrical faults and ensuring reliable performance in demanding conditions.

 

 

SCREEN

 

 

Tinned copper and nylon braid, along with a semiconductive elastomer screen, provide effective shielding for phase cores, protecting against electromagnetic interference and ensuring signal integrity. This screen enhances the cable’s performance and reliability in harsh mining environments.

 

 

LAYUP

 

 

All phase cores are laid up in contact with each other, optimizing space utilization while maintaining electrical integrity. Additionally, two ground cores and one pilot core are laid up in between, facilitating proper grounding and ensuring consistent power distribution within the cable.

 

 

BEDDING

 

 

An elastomeric compound serves as bedding, providing additional insulation and mechanical protection. This layer enhances the cable’s resistance to environmental factors and mechanical stresses encountered in mining operations, ensuring long-term reliability and performance.

 

 

REINFORCEMENT

 

 

The cable incorporates an open weave braid for reinforcement, enhancing its mechanical strength and resistance to external forces. This reinforcement layer ensures the cable’s durability and longevity, even under harsh operating conditions in mining environments.

 

 

OUTER SHEATH

 

 

Encased in an extra heavy-duty elastomer outer sheath, compliant with AS/NZS 3808 standards, the cable offers superior resistance to abrasion, chemicals, and environmental factors. This protective sheath ensures long-term reliability and performance in demanding mining applications.

 

 

RELATED STANDARDS

 

 

The Type 450 Mining Cable complies with AS/NZS 2802 standards, ensuring adherence to safety, performance, and quality requirements for mining cables.

 

 

RATED VOLTAGE

 

 

The cable is rated for voltages of 3.3/3.3 kV, 6.6/6.6 kV, 11/11 kV, and 22/22 kV, making it suitable for various power distribution and equipment connectivity applications within mining operations.

 

 

TEST VOLTAGE

 

 

During manufacturing, the cable undergoes rigorous testing, including test voltages of 12 kV, 22 kV, 30 kV, and 45 kV, ensuring compliance with industry standards and validating its electrical integrity and insulation properties.

 

 

 

 

 

 

 

NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 0 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 1 NSHTÖU-SM Heavy-Duty Cable 600/1kV Designed To Withstand Frequent Reeling And Unreeling For Mobile Equipment Conveyors 2

 

 

 

 

 

 

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.